Journal articles, conference posters, and abstracts on eXaSkin high-density bolus. Spanish posters include English companion material or summaries.

Journal articles

2026 · Peer-reviewed dosimetry and clinical study

Dosimetric and clinical validation of a high-density bolus for superficial skin tumors treated with radiotherapy

Dadoun J et al. Journal of Applied Clinical Medical Physics. 2026;27(8):e70718.

The investigators tested a 1 cm high-density bolus with 6 MV flattening-filter-free beams in a phantom and retrospectively reviewed 55 patients. Acuros XB gave the closest agreement with measured depth dose. Skin dose reductions in the air-gap tests varied with field size and gap thickness.

2021 · Peer-reviewed phantom study

Dosimetric comparison of collapsed cone convolution/superposition and anisotropic analytic algorithms in the presence of Exaskin bolus in radiotherapy

Mohammadian L, Bakhshandeh M, Saeedzadeh E, Jabbari Arfaee A. Iranian Journal of Medical Physics. 2021;18:438–443.

The study compared calculated and film-measured doses in a heterogeneous phantom with 5 mm eXaSkin. With bolus, gamma pass rates at 3%/3 mm were 95.5% for AAA and 97.5% for collapsed cone convolution/superposition.

2020 · Peer-reviewed phantom study

eXaSkin: A novel high-density bolus for 6 MV X-rays radiotherapy

Al-Sudani TA et al. Physica Medica. 2020;80:42–46.

The authors compared eXaSkin with Superflab in an anthropomorphic phantom, assessing agreement between measured and calculated doses for static photon fields and VMAT.

2017 · Published case report

Ewing sarcoma of the testis: A case report and review of the literature

Peinado-Serrano J, Chinchón-Espino D, Biscuola M, Ortiz-Gordillo MJ. Integrative Cancer Science and Therapeutics. 2017;4(1).

This case report documents how eXaSkin was used as part of a postoperative radiotherapy setup, alongside a custom positioning cushion. It describes a single case.

Conference materials

2026 · Conference presentation

eXaSkin and eaSyFix at ASRT 2026

Alejandro Brussain, Anatomical Geometry. ASRT Radiation Therapy Conference, 2026.

The presentation uses clinical examples to illustrate custom eXaSkin bolus and eaSyFix positioning with Moldcare. It includes setup photographs and selected dosimetry examples.

2026 · Conference poster and published abstract

Robust dosimetry at the high-density moldable bolus edge transition despite submillimetric thickness and electronic disequilibrium

Sánchez-Esperón J, Picón-García F, Juan-Martos E, Velázquez-Miranda S. Physica Medica. 2026;149.

The authors evaluated dose at the transition of a stepped eXaSkin bolus, with thicknesses from 0.8 to 7.8 mm, using film measurements and Acuros XB. The mean gamma value was 0.13 under the study’s 3%/3 mm criterion.

2020 · EFOMP conference poster

Bolus as a shaper in the superficial lesions treatment with an electron beam

Derecho-Torres FA, López-Martín N, Velázquez-Miranda S, Luís-Simón FJ. EFOMP, 2020.

A phantom experiment examined a molded eXaSkin ring as a beam-shaping material for 6 MeV electrons. In this setup, film verification reported a 93.28% gamma pass rate at 3%/3 mm.

2019 · Published conference paper

Dose build up characteristics with eXaSkin bolus during 6 MV radiotherapy: MOSkin dosimetry results

Al-Sudani T et al. Journal of Physics: Conference Series. 2019;1154:012024.

The researchers compared eXaSkin and solid water using MOSkin and an advanced Markus chamber. The measured depth of maximum dose was about 9 mm in eXaSkin versus 15 mm in solid water in the reported 6 MV setup.

2018 · AAPM conference report

Customized bolus is more effective than standard bolus to mitigate the increase in exit dose during MRI-guided radiation therapy

David S, Lee H, Ibbott G. AAPM Annual Meeting, 2018.

The authors compared molded eXaSkin, 3D printed PLA, and Superflab for exit surface dose on three phantoms. In the MR-linac tests, the effect depended on phantom shape and whether ultrasound gel was used.

2018 · ESTRO 37 poster · EP-2174

Fabrication of three-dimensional printed customized bolus for the irregular shape of the outer ear

Baeza M et al. ESTRO 37, 2018.

A head phantom study compared a 3D printed outer-ear bolus, eXaSkin, and no bolus. The two bolus plans showed similar target coverage in the reported comparison, with some air gaps visible for both boluses.

2013 · Published conference abstract

Dosimetric characterization of eXaSkin: High density bolus for photon use

Ortiz Seidel M et al. Reports of Practical Oncology and Radiotherapy. 2013;18(Suppl 1):S355.

An early conference report on the dosimetric characterization of eXaSkin for photon radiotherapy.

2012 · ESTRO 31 poster · EP-1235

New high density bolus: A new approach to treatment of superficial tumours with photons

Ortiz M, Velázquez S. ESTRO 31, 2012.

The investigators compared measured 6 MV depth dose curves with and without a 1 cm high-density bolus and assessed agreement with treatment planning calculations.

Spanish posters and English companions

Phantom study · Spanish poster and English submission

Dosimetric impact of thickness variations in moldable high-density boluses for 6 MV VMAT treatments

Evaluación de la criticidad de la relación dosis-espesor en bólus maleables de alta densidad para VMAT

Javier Sánchez-Esperón and colleagues. Hospital Universitario Virgen del Rocío, Seville.

In a 6 MV VMAT phantom test with stepped eXaSkin thicknesses of 3, 7, and 12 mm, the investigators reported less than 2% variation in surface dose across the tested steps and a 95% film gamma pass rate at 2%/2 mm. The Spanish poster and English submission report the same experiment.

2018 · SAC clinical case poster · English summary

Treatment of nonmelanoma skin cancer with VMAT: The SPOT project

Tratamiento del cáncer de piel no melanoma mediante VMAT: Proyecto SPOT

Serradilla A et al. SAC, 2018.

The poster describes a 90-year-old patient with recurrent squamous cell carcinoma behind the ear who was treated using image-guided VMAT. The team molded eXaSkin over the area and used a thermoplastic mask for positioning. The authors reported transient grade 2 skin reaction and a complete clinical response at two months in this case.

2017 · SEFM & SEPR poster · English summary

Dosimetric implications of unintended air gaps beneath high-density bolus

Implicaciones dosimétricas de la presencia de airgaps indeseados bajo el bolus de alta densidad

Gil Conde M, Ortiz Seidel M, Velázquez Miranda S. SEFM & SEPR, 2017.

The investigators used radiochromic film to measure 6 MV surface dose with eXaSkin in contact and with 1, 2, and 3 cm gaps. Surface dose fell as the gap increased, with a larger decrease for the smaller field. In one recalculated clinical example, a simulated 1 cm gap preserved prescription isodose coverage. The findings apply to the specific setups tested.

Additional source materials are available in AnatGe’s publication archive ↗.